  "mitigation_id": "M00001",
  "chemical_id": "pfoa",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Anion exchange, GAC, reverse osmosis, nanofiltration",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.61(d) Table 3",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_61",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.61 Maximum contaminant levels for organic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.61",
  "access_date": "2026-11-23",
  "evidence": "| PFOA | Anion exchange, GAC, reverse osmosis, nanofiltration. |",
  "locator": "char offset 7859 in data/text/us_ecfr_141_61.txt"
 },
 {
  "mitigation_id": "M00002",
  "chemical_id": "pfos",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Anion exchange, GAC, reverse osmosis, nanofiltration",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.61(d) Table 3",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_61",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.61 Maximum contaminant levels for organic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.61",
  "access_date": "2026-11-23",
  "evidence": "| PFOS | Anion exchange, GAC, reverse osmosis, nanofiltration. |",
  "locator": "char offset 7922 in data/text/us_ecfr_141_61.txt"
 },
 {
  "mitigation_id": "M00003",
  "chemical_id": "pfhxs",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Anion exchange, GAC, reverse osmosis, nanofiltration",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.61(d) Table 3",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_61",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.61 Maximum contaminant levels for organic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.61",
  "access_date": "2026-11-23",
  "evidence": "| PFHxS | Anion exchange, GAC, reverse osmosis, nanofiltration. |",
  "locator": "char offset 7732 in data/text/us_ecfr_141_61.txt"
 },
 {
  "mitigation_id": "M00004",
  "chemical_id": "pfna",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Anion exchange, GAC, reverse osmosis, nanofiltration",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.61(d) Table 3",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_61",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.61 Maximum contaminant levels for organic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.61",
  "access_date": "2026-11-23",
  "evidence": "| PFNA | Anion exchange, GAC, reverse osmosis, nanofiltration. |",
  "locator": "char offset 7796 in data/text/us_ecfr_141_61.txt"
 },
 {
  "mitigation_id": "M00005",
  "chemical_id": "hfpo_da",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Anion exchange, GAC, reverse osmosis, nanofiltration",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.61(d) Table 3",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_61",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.61 Maximum contaminant levels for organic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.61",
  "access_date": "2026-11-23",
  "evidence": "| HFPO-DA | Anion exchange, GAC, reverse osmosis, nanofiltration. |",
  "locator": "char offset 7666 in data/text/us_ecfr_141_61.txt"
 },
 {
  "mitigation_id": "M00006",
  "chemical_id": "pfas_hazard_index_us",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Anion exchange, GAC, reverse osmosis, nanofiltration",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.61(d) Table 3",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_61",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.61 Maximum contaminant levels for organic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.61",
  "access_date": "2026-11-23",
  "evidence": "Hazard Index PFAS (HFPO-DA, PFBS, PFHxS, and PFNA) | Anion exchange, GAC, reverse osmosis, nanofiltration. |",
  "locator": "char offset 7559 in data/text/us_ecfr_141_61.txt"
 },
 {
  "mitigation_id": "M00007",
  "chemical_id": "arsenic",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology codes (US EPA; see key in 40 CFR 141.62(c)): 1, 2, 5, 6, 7, 9, 12",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.62(c)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "Footnote 4: BATs for Arsenic V; pre-oxidation may be required to convert Arsenic III to Arsenic V.",
  "source_id": "us_ecfr_141_62",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.62 Maximum contaminant levels for inorganic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.62",
  "access_date": "2026-11-23",
  "evidence": "| Arsenic 4 | 1, 2, 5, 6, 7, 9, 12 5 |",
  "locator": "char offset 1641 in data/text/us_ecfr_141_62.txt"
 },
 {
  "mitigation_id": "M00008",
  "chemical_id": "arsenic",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Key to US EPA BAT codes: 1 = Activated Alumina 2 = Coagulation/Filtration (not BAT for systems <500 service connections) 3 = Direct and Diatomite Filtration 4 = Granular Activated Carbon 5 = Ion Exchange 6 = Lime Softening (not BAT for systems <500 service connections) 7 = Reverse Osmosis 8 = Corrosion Control 9 = Electrodialysis 10 = Chlorine 11 = Ultraviolet 12 = Oxidation/Filtration 13 = Alkaline Chlorination (pH ≥8.5)",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.62(c)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_62",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.62 Maximum contaminant levels for inorganic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.62",
  "access_date": "2026-11-23",
  "evidence": "Key to BATS in Table 1 = Activated Alumina 2 = Coagulation/Filtration (not BAT for systems <500 service connections) 3 = Direct and Diatomite Filtration 4 = Granular Activated Carbon 5 = Ion Exchange 6 = Lime Softening (not BAT for systems <500 service connections) 7 = Reverse Osmosis 8 = Corrosion Control 9 = Electrodialysis 10 = Chlorine 11 = Ultraviolet 12 = Oxidation/Filtration 13 = Alkaline Chlorination (pH ≥8.5)",
  "locator": "char offset 2205 in data/text/us_ecfr_141_62.txt"
 },
 {
  "mitigation_id": "M00009",
  "chemical_id": "nitrate",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology codes (US EPA; see key in 40 CFR 141.62(c)): 5,7,9",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.62(c)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_62",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.62 Maximum contaminant levels for inorganic contaminants (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.62",
  "access_date": "2026-11-23",
  "evidence": "| Nitrate | 5,7,9 |",
  "locator": "char offset 1848 in data/text/us_ecfr_141_62.txt"
 },
 {
  "mitigation_id": "M00010",
  "chemical_id": "bromate",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Control of ozone treatment process to reduce production of bromate",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.64(a)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_64",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.64 Maximum contaminant levels for disinfection byproducts (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.64",
  "access_date": "2026-11-23",
  "evidence": "| Bromate | Control of ozone treatment process to reduce production of bromate |",
  "locator": "char offset 1052 in data/text/us_ecfr_141_64.txt"
 },
 {
  "mitigation_id": "M00011",
  "chemical_id": "chlorite",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Control of treatment processes to reduce disinfectant demand and control of disinfection treatment processes to reduce disinfectant levels",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.64(a)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_64",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.64 Maximum contaminant levels for disinfection byproducts (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.64",
  "access_date": "2026-11-23",
  "evidence": "| Chlorite | Control of treatment processes to reduce disinfectant demand and control of disinfection treatment processes to reduce disinfectant levels |",
  "locator": "char offset 1131 in data/text/us_ecfr_141_64.txt"
 },
 {
  "mitigation_id": "M00012",
  "chemical_id": "trihalomethanes_total",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Enhanced coagulation or enhanced softening or GAC10, with chlorine as the primary and residual disinfectant",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.64(b)(1)(ii)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_64",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.64 Maximum contaminant levels for disinfection byproducts (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.64",
  "access_date": "2026-11-23",
  "evidence": "Total trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) | Enhanced coagulation or enhanced softening or GAC10, with chlorine as the primary and residual disinfectant |",
  "locator": "char offset 2241 in data/text/us_ecfr_141_64.txt"
 },
 {
  "mitigation_id": "M00013",
  "chemical_id": "haloacetic_acids",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "Best available technology (US EPA): Enhanced coagulation or enhanced softening or GAC10, with chlorine as the primary and residual disinfectant",
  "level": "engineering (water treatment)",
  "jurisdiction": "US",
  "instrument": "40 CFR 141.64(b)(1)(ii)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "us_ecfr_141_64",
  "citation": "US EPA / Office of the Federal Register (eCFR). 40 CFR 141.64 Maximum contaminant levels for disinfection byproducts (eCFR, current).",
  "citation_url": "https://www.ecfr.gov/current/title-40/chapter-I/subchapter-D/part-141/subpart-G/section-141.64",
  "access_date": "2026-11-23",
  "evidence": "Total trihalomethanes (TTHM) and Haloacetic acids (five) (HAA5) | Enhanced coagulation or enhanced softening or GAC10, with chlorine as the primary and residual disinfectant |",
  "locator": "char offset 2241 in data/text/us_ecfr_141_64.txt"
 },
 {
  "mitigation_id": "M00014",
  "chemical_id": "pfoa",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "DWI Tier 3 requirement: companies to put in place emergency contingency measures to reduce concentrations to below 0",
  "level": "regulatory",
  "jurisdiction": "GB-EAW",
  "instrument": "DWI PFAS guidance v1.1 (2025) para 2.10",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "uk_dwi_pfas_2025",
  "citation": "Drinking Water Inspectorate (England and Wales). DWI Guidance on the requirements for PFAS in drinking water (March 2025).",
  "citation_url": "https://dwi-production-files.s3.eu-west-2.amazonaws.com/wp-content/uploads/2025/03/24141825/DWI_PFAS-Guidance_Mar_2025.pdf",
  "access_date": "2026-11-23",
  "evidence": "2.10 Where sites fall into tier 3 (≥0.1 µg/L), the Inspectorate expects companies to put in place emergency contingency measures to reduce concentrations to below 0.",
  "locator": "char offset 9068 in data/text/uk_dwi_pfas_2025.txt"
 },
 {
  "mitigation_id": "M00015",
  "chemical_id": "pfos",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "DWI Tier 3 requirement: companies to put in place emergency contingency measures to reduce concentrations to below 0",
  "level": "regulatory",
  "jurisdiction": "GB-EAW",
  "instrument": "DWI PFAS guidance v1.1 (2025) para 2.10",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "uk_dwi_pfas_2025",
  "citation": "Drinking Water Inspectorate (England and Wales). DWI Guidance on the requirements for PFAS in drinking water (March 2025).",
  "citation_url": "https://dwi-production-files.s3.eu-west-2.amazonaws.com/wp-content/uploads/2025/03/24141825/DWI_PFAS-Guidance_Mar_2025.pdf",
  "access_date": "2026-11-23",
  "evidence": "2.10 Where sites fall into tier 3 (≥0.1 µg/L), the Inspectorate expects companies to put in place emergency contingency measures to reduce concentrations to below 0.",
  "locator": "char offset 9068 in data/text/uk_dwi_pfas_2025.txt"
 },
 {
  "mitigation_id": "M00016",
  "chemical_id": "pfoa",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "WHO advice to Member States: strive to achieve concentrations in drinking-water that are as low as reasonably practical",
  "level": "regulatory",
  "jurisdiction": "WHO",
  "instrument": "WHO PFAS web page (key principles from the draft background document)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "who_pfas_status",
  "citation": "World Health Organization. WHO web page: Per- and polyfluoroalkyl substances (chemical hazards in drinking-water).",
  "citation_url": "https://www.who.int/teams/environment-climate-change-and-health/water-sanitation-and-health/chemical-hazards-in-drinking-water/per-and-polyfluoroalkyl-substances",
  "access_date": "2026-11-23",
  "evidence": "Member States should strive to achieve concentrations in drinking-water that are as low as reasonably practical.",
  "locator": "char offset 5839 in data/text/who_pfas_status.txt"
 },
 {
  "mitigation_id": "M00017",
  "chemical_id": "pfos",
  "source_ref": "drinking_water",
  "category": "drinking_water",
  "strategy": "WHO advice to Member States: strive to achieve concentrations in drinking-water that are as low as reasonably practical",
  "level": "regulatory",
  "jurisdiction": "WHO",
  "instrument": "WHO PFAS web page (key principles from the draft background document)",
  "effectiveness": "not quantified in source (regulatory designation of best available technology)",
  "quantified_reduction": "",
  "notes": "",
  "source_id": "who_pfas_status",
  "citation": "World Health Organization. WHO web page: Per- and polyfluoroalkyl substances (chemical hazards in drinking-water).",
  "citation_url": "https://www.who.int/teams/environment-climate-change-and-health/water-sanitation-and-health/chemical-hazards-in-drinking-water/per-and-polyfluoroalkyl-substances",
  "access_date": "2026-11-23",
  "evidence": "Member States should strive to achieve concentrations in drinking-water that are as low as reasonably practical.",
  "locator": "char offset 5839 in data/text/who_pfas_status.txt"
 }
]